News: Peace's solar power area is 205MW in Fresno County, California; the golden state has been operating since 2016. In 2021, the supporting solar energy area sustaining two battery power storage space systems (BESS), with a complete range of 72 mW/288MWH, to aid in easing intermittent troubles in power generation and improve the total power generation efficiency of solar power fields.
For the procedure of a battery energy storage system for the operating solar power field, it is required to reconsider the control device of the power generation field since while taking care of and running the solar energy field, the inverter of the battery energy storage system needs to likewise be incorporated. Its specifications require it to abide by the stringent arrangements of California Independent System Operators (CAISO) and electricity acquisition contracts.
The demands for the controller are complicated. The controller provides accumulated and independent operational procedures and the ability to regulate power generation possessions. Its needs include:
· The solar power generation facilities, as well as battery power storage space systems, are handled as different energy properties, which are used for power transfer, California independent system drivers (CAISO), and contractors.
· Protect against a mix of solar power facilities and battery power storage systems that go beyond the power ability of the grid by grid and also might harm the transformer in the substation.
· Handle the power abandonment of solar power generation centers to provide top priority to charging the power storage system rather than reducing solar power generation.
· Incorporate the electric tool of the power storage system and the solar energy field.
Under normal conditions, such a system configuration needs several hardware-based controllers, which depend on the long-array terminal device (RTU) or programmable logic controllers (PLC) divided by separate programs. Making certain such an intricate system composed of a single system is constantly effective. It is a massive obstacle that requires a lot of sources to enhance and also get rid of failures.
On the other hand, it will be regulated by a software-based controller, and systematized control of the entire site is a much more exact, scalable, and also efficient solution. This is picked by the proprietor of solar power generation centers when installing sustainable power generation facilities (PPC).
Solar power generation controllers (PPC) can supply simultaneous and collaborated control. This ensures that the present, as well as the voltage of each substation and the voltage of each substation, can fulfill all operating needs and maintain it within the range of the technical constraints of the power system.
One means to achieve this goal is to proactively regulate the outcome power of solar energy generation centers and battery power storage space systems to ensure that its outcome power is lower than the rated value of the transformer. Use a 100-millisecond comments control circuit for scanning, and the renewable energy power generation controller (PAY PER CLICK) likewise sends the actual power setup point to the SCADA monitoring system of the battery monitoring system (EMS) as well as solar energy generation centers. If the battery power storage system is called for to release, and also the discharge quantity will cause the rated worth of the transformer, the controller or reduces the solar energy generation before the battery power storage space system is released; The overall discharge of solar energy generation facilities is lower than the rated worth of the transformer.
The controller makes independent decisions based on the client's organization's priority, which is one of the benefits of the optimization function of the controller. The controller uses forecast analysis and artificial intelligence modern technology within the scope of supervision and power purchase arrangements, as well as chooses based on the client's optimum interests, as opposed to securing the charging/discharge mode of a specific time in the day.
Software methods of solar+power storage space tasks to address intricate troubles connected to the range of public usage of solar power facilities and also battery power storage space systems. In the past, hardware-based solutions could not be comparable to artificial intelligence aid technologies that have performed well in terms of effectiveness, speed, and precision today. Software program-based sustainable power generation controller (PAY PER CLICK) gives a scalable, future-oriented service and prepares for the intricacy of the energy market in the 21st century.
One method to accomplish this goal is to proactively control the outcome power of solar power generation centers and battery energy storage systems to ensure that its result power is reduced than the rated value of the transformer. Use a 100-millisecond comments control circuit for scanning, as well as the renewable energy power generation controller (PPC), which likewise sends the real power setting factor to the SCADA monitoring system of the battery management system (EMS) and solar power generation centers. If the battery energy storage space system is called for to discharge, as well as the discharge quantity will trigger the ranked value of the transformer and the controller or decreases the solar power generation before the battery energy storage system is discharged; The complete discharge of solar power generation facilities is reduced than the rated value of the transformer.
Software approaches of solar+energy storage tasks to resolve complex issues related to the scale of public usage of solar power facilities and battery power storage systems. Software program-based renewable power generation controller (PPC) gives a scalable, future-oriented solution and prepares for the intricacy of the energy market in the 21st century.